Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Arq. bras. oftalmol ; 84(3): 230-234, May-June 2021. tab, graf
Article in English | LILACS | ID: biblio-1248960

ABSTRACT

ABSTRACT Purpose: This study aimed to investigate the effect of using a viscoelastic substance in Descemet's membrane rupture in "double bubble" deep anterior lamellar keratoplasty. Methods: The medical records and videos of surgeries of 40 patients who underwent surgery between January 2014 and July 2015 were retrospectively evaluated. The patients were divided into two groups: 20 patients whose perforation of the posterior stromal wall was performed without administration of any viscoelastic substance (group 1) and 20 patients whose perforation of the posterior stromal wall was performed with administration of viscoelastic substance onto the posterior stroma (group 2). The Descemet's membrane perforation rate was compared between groups. Results: Perforation of the Descemet's membrane was observed in 12 (60.0%) patients in group 1 and only three (15.0%) patients in group 2. This difference was statistically significant (p=0.003). Only one (5%) patient in group 2 had macroperforation during the procedure, and the surgery was converted to penetrating keratoplasty. Eleven (55.0%) patients in group 1 had macroperforation of Descemet's membrane, and surgeries were converted to penetrating keratoplasty. This difference between the groups was statistically significant (p=0.001). Conclusions: Administering a viscoelastic substance onto the posterior stromal side just before puncture is an effective method to decrease the risk of Descemet's membrane perforation in deep anterior lamellar keratoplasty.(AU)


RESUMO Objetivo: Investigar o efeito do uso de uma substância viscoelástica na ruptura da membrana de Descemet em casos de ceratoplastia lamelar anterior profunda em "bolha dupla". Métodos: Foram avaliados retrospectivamente prontuários e vídeos de cirurgias de 40 pacientes operados entre janeiro de 2014 e julho de 2015. Os pacientes foram divididos em dois grupos: 20 pacientes nos quais a parede posterior do estroma foi puncionada sem a colocação de nenhuma substância viscoelástica (grupo 1) e 20 pacientes nos quais uma substância viscoelástica foi aplicada sobre o estroma posterior ao ser puncionada a parede posterior do estroma (grupo 2). A taxa de perfuração da membrana de Descemet foi comparada entre os grupos. Resultados: Observou-se perfuração da membrana de Descemet em 12 casos (60,0%) no grupo 1 e em apenas 3 casos (15,0%) no grupo 2. Essa diferença foi estatisticamente significativa (p=0,003). Apenas um caso (5%) no grupo 2 teve macroperfuração durante o procedimento, sendo a cirurgia então convertida em uma ceratoplastia penetrante. Onze casos (55,0%) no grupo 1 tiveram macroperfuração da membrana de Descemet e essas cirurgias foram convertidas em ceratoplastias penetrantes. Essa diferença entre os grupos foi estatisticamente significativa (p=0,001). Conclusões: A aplicação de substância viscoelástica sobre o lado posterior do estroma logo antes da punção é um método eficaz para diminuir o risco de perfuração da membrana de Descemet na ceratoplastia lamelar anterior profunda.(AU)


Subject(s)
Humans , Corneal Transplantation/instrumentation , Descemet Membrane/surgery , Viscoelastic Substances , Corneal Stroma
2.
Rev. bras. oftalmol ; 73(5): 279-281, Sep-Oct/2014. graf
Article in English | LILACS | ID: lil-741904

ABSTRACT

Objective: We describe a novel spatula and dissector to facilitate the big-bubble technique in deep anterior lamellar keratoplasty (DALK). Methods: A 29-year-old man who was diagnosed with bilateral keratoconus underwent deep anterior lamellar keratoplasty (DALK). After 350μm partial thickness incision of the recipient cornea, the Bonfadini dissector was inserted at the deepest point in the peripheral incision and could be advanced to the center of the cornea safely because of its "semi-sharp" tip. After achieving the big-bubble (BB) separation of Descemet membrane (DM) from the overlying stroma, the anterior stromal disc was removed. Viscoelastic material was placed on the stromal bed to prevent uncontrolled collapse and perforation of DM during the paracentesis blade incision into the BB. We could detect the safe opening of the BB using the Bonfadini dissector by the leakage of air bubbles into the viscoelastic material. After injecting viscoelastic material into the BB space, we inserted the Bonfadini spatula into the bigbubble safely because of its curved profile and blunt edges. The groove along the length of the Bonfadini spatula enables safe and efficient incision or the residual stromal tissue using the pointed end of a sharp blade while protecting the underlying DM. After removal of posterior stroma, the donor button was sutured with 16 interrupted 10-0 nylon sutures. Results: This technique and the use of the Bonfadini spatula and dissector facilitate exposure of Descemet membrane. Conclusion: The smooth Bonfadini DALK spatula and dissector facilitate safe and efficient completion of DALK surgery. .


Objetivo: Descrevemos o uso de novos instrumentais cirúrgicos para facilitar a técnica de "big-bubble" na ceratoplastia lamelar anterior profunda (DALK). Métodos: Paciente masculino, 29 anos, foi diagnosticado com ceratocone bilateral e submetido à ceratoplastia lamelar anterior profunda (DALK). Após incisão da córnea receptora numa profundidade de 350μm de espessura parcial, o dissector Bonfadini foi inserido no ponto mais profundo da incisão periférica e pode avançar para o centro da córnea com segurança devido à sua ponta semiafiada. Depois de realizar a "big-bubble" (BB) e atingir a separação da Membrana de Descemet (MD) do estroma sobrejacente, o disco corneano de estroma anterior foi removido. Um viscoelástico foi colocado sobre o leito do estroma remanescente para impedir o colapso não-controlado e perfuração da MD durante a incisão na BB com lâmina de paracentese. Verificamos segurança no rompimento do estroma remanescente com o auxílio do dissector Bonfadini, para liberação da bolha de ar da BB através do viscoelástico. Depois de injetar o viscoelástico no espaço da BB, inserimos a espátula Bonfadini neste espaço, o que demonstrou-se seguro devido ao formato curvo e das bordas arredondadas do instrumental. A chanfradura ao longo do comprimento da espátula Bonfadini permite a incisão pela ponta de uma lâmina afiada, protegendo assim a MD subjacente. Após a remoção do estroma posterior, o botão doador foi suturado com 16 pontos interrompidos de fio nylon 10.0. Resultados: Esta técnica e o uso da espátula Bonfadini e dissector facilitam a exposição de membrana de Descemet. Conclusão: A superfície lisa da espátula Bonfadini e dissector, facilitam a realização segura e eficiente da ceratoplastia lamelar anterior profunda (DALK). .


Subject(s)
Humans , Male , Adult , Corneal Transplantation/instrumentation , Corneal Transplantation/methods , Keratoplasty, Penetrating/instrumentation , Keratoplasty, Penetrating/methods , Descemet Membrane/surgery , Keratoconus/surgery , Rupture/prevention & control , Descemet Membrane/injuries
4.
Rev. bras. oftalmol ; 73(2): 71-74, Mar-Apr/2014. tab, graf
Article in English | LILACS | ID: lil-718435

ABSTRACT

Purpose: To evaluate the efficacy and reliability of a low-energy femtosecond laser with a high repetition rate for construction of deep anterior donor corneal lamellae. Methods: This was a prospective laboratory investigation. Twenty-five human corneal buttons were femtosecond laser cut to create thick anterior lamellae (diameter, 10mm; thickness, 500µm). The laser cuts were made using an LDV® femtosecond laser in a Ziemer® anterior chamber. To obtain a better edge, the lamellae were trephined with an 8mm trephine (Katena®). The central corneal thickness and the anterior lamellae were measured using a Mitutoyo® thickness gauge with an accuracy of 0.001mm. Results: The central thickness of the 25 corneas ranged from 500 to 705µm (mean, 584 ± 51µm). The thickness of the anterior lamellae ranged from 420 to 480µm (mean, 455 ± 12.7µm). The anterior lamellae diameters were 7.90 ± 0.1mm, and all laser cuts were round. The lamellar interfaces appeared regular by surgical microscopy. There were no cases of inter-lamellar adhesion. Conclusion: The LDV® femtosecond laser appears to be a safe and reliable instrument for cutting deep anterior lamellae from donor corneoscleral buttons. Minimal variation in donor lamellar depth with the laser will be useful for creating donor corneal tissue for deeper anterior lamellar keratoplasty or endothelial keratoplasty surgery or both from a single donor cornea. .


Objetivo: Avaliar a eficácia e segurança de um laser de femtossegundo de baixa energia e alta taxa de repetição para confecção de lamelas corneanas doadoras anteriores profundas. Métodos: Este é um estudo prospectivo de investigação laboratorial. Vinte e cinco botões corneanos foram cortados com laser de femtossegundo para criar lamelas corneanas doadoras anteriores profundas (diâmetro, 10mm; espessura, 500µm). O corte a laser foi realizado com femtosecond laser LDV® na câmara anterior artificial da Ziemer®. Para obter-se uma melhor borda, as lamelas foram trepanadas com um trépano de 8mm da Katena®. A paquimetria corneana central e as lamelas anteriores foram aferidas utilizando o paquímetro Mitutoyo®, com acurácia de 0.001mm. Resultados: A paquimetria central das 25 córneas variou de 500 a 705µm (média de 584 ± 51µm). A espessura das lamelas anteriores variou de 420 a 480µm (media de 455 ± 12.7µm). O diâmetro das lamelas corneanas doadoras foi 7.90 ± 0,1mm, sendo todos os cortes redondos. As interfaces lamelares apresentaram-se regular ao microscópio cirúrgico. Não houve casos de adesão interlamelar. Conclusão: O laser de femtossegundo LDV® mostrou-se seguro e eficaz para confeccionar lamelas corneanas doadoras a partir de botões córneo-esclerais. Mínima variação na espessura das lamelas doadoras confeccionadas com o laser será útil para criação de tecidos corneanos doadores para ceratoplastia lamelar anterior profunda ou ceratoplastia endoteliais, ou ambas, a partir de uma só córnea. .


Subject(s)
Humans , Tissue Donors , Corneal Transplantation/instrumentation , Corneal Transplantation/methods , Tissue and Organ Harvesting/methods , Lasers , Endothelium, Corneal/transplantation , Prospective Studies , Cornea/anatomy & histology , Corneal Topography , Dissection/instrumentation , Dissection/methods , Corneal Pachymetry/instrumentation , Corneal Pachymetry/methods
5.
Arq. bras. oftalmol ; 69(2): 151-155, mar.-abr. 2006. ilus
Article in Portuguese | LILACS | ID: lil-426707

ABSTRACT

OBJETIVO: Descrever as características de uma nova câmara anterior artificial e discutir suas vantagens (MALKS®, Loktal, São Paulo, Brasil). MÉTODOS: Análise e descrição das especificações técnicas utilizadas na câmara anterior artificial MALKS® (Micro automated lamellar keratoplasty system). RESULTADOS: O MALKS® é constituído de oito partes: a) câmara artificial; b) anel fixador da córnea; c) porca de travamento do anel fixador; d) trilho e ajustador do diâmetro do disco lamelar; e) aplanadores para aferição e definição do diâmetro do disco lamelar; f) sistema de infusão, que possibilita o controle digital objetivo peroperatório da pressão intracameral; g) microcerátomo automático; h) trépano marcador. CONCLUSÃO: O MALKS® utiliza o mesmo microcerátomo automático desenvolvido para LASIK, possibilita a obtenção de lamelas corneanas de espessura e diâmetro programados, assim como o controle objetivo peroperatório digital da pressão intracameral (PIC). Esta câmara anterior artificial pode ser ferramenta importante tanto para as cirurgias de transplante lamelar superficial quanto endotelial.


Subject(s)
Humans , Corneal Transplantation/instrumentation , Keratomileusis, Laser In Situ/instrumentation , Keratoplasty, Penetrating/instrumentation , Tissue and Organ Harvesting/instrumentation , Anterior Chamber , Corneal Transplantation/methods , Equipment Design , Endothelium, Corneal/transplantation , Keratoplasty, Penetrating/methods
SELECTION OF CITATIONS
SEARCH DETAIL